NEN 10617-7:1996 en

Normomslag

Grafische symbolen voor elektrotechnische tekeningen - Deel 7: Schakelmaterieel en beveiligingsmiddelen

Status: Ingetrokken
Publicatiedatum: 01-08-1996 Bekijk een preview
Taal Grootte Prijs  
3,2 Mb € 163,36
68 pag € 163,36
  • Omschrijving
    • Gives symbols on contacts (qualifying symbols: contacts with two or three positions; passing contacts with two positions; early and late operating contacts; examples of contacts with intentional delay; examples of spring return and non-spring return (stay put) contacts), switches, switchgears and starters (single-pole switches; position and limit switches; temperature sensitive switches; speed change sensitive contacts, mercury and levelling switches; examples of multi-pole and multi-position switches; block symbols for complex switches; switchgear and controlgear; block symbols for motor starters), electromechanical all-or-nothing relays (operating devices), measuring relays and related devices (block symbol and qualifying symbols; examples of measuring relays; other devices), proximity and touch-sensitive devices (sensors and detectors; switches), protective devices (fuses and fuse-switches; gaps and arrestors; fire-extinguishers), miscellaneous symbols (igniters and flag-indicators), older symbols for contacts, switchgear and protective devices.

  • Details
    • ICS - code(s) 01.080.40:
      29.130.01:

    • Nederlandse titel Grafische symbolen voor elektrotechnische tekeningen - Deel 7: Schakelmaterieel en beveiligingsmiddelen
    • Engelse titel Graphical symbols for diagrams - Part 7: Switchgear, controlgear and protective devices
    • Engelse samenvatting Gives symbols on contacts (qualifying symbols: contacts with two or three positions; passing contacts with two positions; early and late operating contacts; examples of contacts with intentional delay; examples of spring return and non-spring return (stay put) contacts), switches, switchgears and starters (single-pole switches; position and limit switches; temperature sensitive switches; speed change sensitive contacts, mercury and levelling switches; examples of multi-pole and multi-position switches; block symbols for complex switches; switchgear and controlgear; block symbols for motor starters), electromechanical all-or-nothing relays (operating devices), measuring relays and related devices (block symbol and qualifying symbols; examples of measuring relays; other devices), proximity and touch-sensitive devices (sensors and detectors; switches), protective devices (fuses and fuse-switches; gaps and arrestors; fire-extinguishers), miscellaneous symbols (igniters and flag-indicators), older symbols for contacts, switchgear and protective devices.
    • Intrekkingsdatum 24-10-2003
  • Auteurs
    • Commissie: Symbolen en tekeningen (NEC 3 / M. Geertzen