Norm

ASME-BPVC 12:2004 en

Rules for Inservice Inspection of Nuclear Power Plant Components

  • Deze norm is ingetrokken sinds 31-07-2007

255,88

Over deze norm

Status Ingetrokken
Aantal pagina's 0
Commissie Drukapparatuur
Gepubliceerd op 01-07-2004
Taal Engels
This Section contains Division 1 and 3, in one volume and provides rules for the examination, inservice testing and inspection, and repair and replacement of components and systems in light-water cooled and liquid-metal cooled nuclear power plants. The Division 2 rules for inspection and testing of components of gas-cooled nuclear power plants have been deleted in the 1995 Edition. With the decommissioning of the only gas-cooled reactor to which these rules apply, there is no apparent need to continue publication of Division 2. Application of this Section of the Code begins when the requirements of the Construction Code have been satisfied. The rules of this Section constitute requirements to maintain the nuclear power plant while in operation and to return the plant to service, following plant outages, and repair or replacement activities. The rules require a mandatory program of scheduled examinations, testing, and inspections to evidence adequate safety. The method of nondestructive examination to be used and flaw size characterization are also contained within this Section.Rules for Light-Water Cooled Nuclear Power Plant Components: General Requirements; Inspection Schedules; NDE Personnel Requirements; Inservice Inspection & Testing; Requirements for Class 1, 2, 3 Components & Their Supports and Class MC and CC Components in Light-Water Cooled Power Plants; Repair and Replacement of Components; System Pressure Tests Requirements; Flaw Detection & Evaluation; Inservice Testing Pumps and Valves; Duties and Responsibilities of the Owner and the Authorized Nuclear Inservice Inspector. Rules for Liquid Metal Cooled Nuclear Power Plant Components; General Requirements; Inspection Schedules; Personnel Requirements; Inservice Inspection & Testing; Requirements for Class 1, 2, & 3 Components (containing liquid metal or cover gas) & Their Supports; Flaw Detection & Evaluation; Repair & Replacement Requirements; Duties and Responsibilities of the Owner and the Authorized Nuclear Inservice Inspector.

Details

ICS-code 23.020.30
Nederlandse titel Rules for Inservice Inspection of Nuclear Power Plant Components
Engelse titel Rules for Inservice Inspection of Nuclear Power Plant Components
Vervangen door

Winkelwagen

Subtotaal:

Ga naar winkelwagen