Norm

ASTM D3824-12

Standard Test Methods for Continuous Measurement of Oxides of Nitrogen in the Ambient or Workplace Atmosphere by the Chemiluminescent Method

61,51

Over deze norm

Status Definitief
Aantal pagina's 12
Commissie D22.03
Gepubliceerd op 01-04-2012
Taal Engels

1.1 These test methods cover procedures for the continuous determination of total nitrogen dioxide (NO2) and nitric oxide (NO) as NOx, or nitric oxide (NO) alone or nitrogen dioxide (NO2) alone, in the ranges shown in the following table:

Range of Concentration
GasAmbient AtmosphereWorkplace Atmosphere
μg/m3 (ppm) (Note 1)mg/m3 (ppm) (Note 1)
NO10 to 600 (0.01 to 0.5)0.6 to 30 (0.5 to 25)
(NO + NO2) = NOx20 to 1000 (0.01 to 0.05)1 to 50 (0.5 to 25)
NO220 to 1000 (0.01 to 0.5)1 to 50 (0.5 to 25)

Note 1—Approximate range: 25°C and 101.3 kPa (1 atm).

1.2 The test methods are based on the chemiluminescent reaction between nitric oxide and ozone.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 9.