Norm

IEC 60898-1:2015 en

Elektrotechnisch installatiematerieel - Installatie-automaten voor huishoudelijke en soortgelijke installaties - Deel 1: Installatie-automaten voor wisselstroom

Volledig inclusief:

274,20

Over deze norm

Status Definitief
Aantal pagina's 147
Gepubliceerd op 01-03-2015
Taal Engels
This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz, 60 Hz or 50/60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. As far as possible, it is in line with the requirements contained in IEC 60947-2. These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained. They are intended for use in an environment with pollution degree 2. They are suitable for isolation. Circuit-breakers of this standard, with exception of those rated 120 V or 120/240 V (see Table 1), are suitable for use in IT systems. This standard also applies to circuit-breakers having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. This standard does not apply to - circuit-breakers intended to protect motors; - circuit-breakers, the current setting of which is adjustable by means accessible to the user. For circuit-breakers having a degree of protection higher than IP20 according to IEC 60529, for use in locations where arduous environmental conditions prevail (e.g. excessive humidity, heat or cold or deposition of dust) and in hazardous locations (e.g. where explosions are liable to occur), special constructions may be required. This standard does not apply to circuit-breakers for a.c. and d.c. operation,which is covered by IEC 60898-2. This standard does not apply to circuit-breakers which incorporate residual current tripping devices, which is covered by IEC 61009-1, IEC 61009-2-1, and IEC 61009-2-2. A guide for co-ordination under short-circuit conditions between a circuit-breaker and another short-circuit protective device (SCPDs) is given in Annex D. For more severe overvoltage conditions, circuit-breakers complying with other standards (e.g. IEC 60947-2) should be used. For an environment with a higher pollution degree, enclosures giving the appropriate degree of protection should be used.

Details

ICS-code 29.120.50
Nederlandse titel Elektrotechnisch installatiematerieel - Installatie-automaten voor huishoudelijke en soortgelijke installaties - Deel 1: Installatie-automaten voor wisselstroom
Engelse titel Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
Vervangt
Gewijzigd door

Winkelwagen

Subtotaal:

Ga naar winkelwagen