Norm

ISO/DIS 14146:2016 en

Stralingsbescherming - Criteria en eigen grenzen voor de periodieke evaluatie van processoren van persoonlijke dosismeters

  • Deze norm is niet direct leverbaar vanuit de NEN-shop.
    Wilt u dit product bestellen neemt u dan contact op met NEN-klantenservice: (015) 2 690 391 of klantenservice@nen.nl

Over deze norm

Status Ontwerp
Aantal pagina's 11
Commissie Radioactiviteit - Toepassing en meten
Gepubliceerd op 12-12-2016
Taal Engels
The quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type-tested) dosimetry system1)) and the training and experience of the staff, together with the calibration procedures and quality assurance programmes. This International Standard specifies the criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and / or area dosemeters. An area dosemeter can be a workplace dosemeter or an environmental dosemeter. The performance verification may be carried out as a part of the approval procedure for the dosimetry system or as an independent check to verify that the dosimetry service fulfils the type test performance requirements specified in an International Standard. This International Standard applies to personal and area dosemeters for the assessment of external photon radiation with a (fluence weighted) mean energy between 5 keV and 10 MeV, beta radiation with a (fluence weighted) mean energy between 60 keV and 1,2 MeV, and neutron radiation with a (fluence weighted) mean energy between 25,3 meV (i.e. thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV) and 200 MeV. It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month). Active dosemeters (for dose measurement) may also be treated according to this International Standard. Then, they should be treated as if they were passive (i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization).

Details

ICS-code 13.280
Nederlandse titel Stralingsbescherming - Criteria en eigen grenzen voor de periodieke evaluatie van processoren van persoonlijke dosismeters
Engelse titel Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services
Vervangt

Winkelwagen

Subtotaal:

Ga naar winkelwagen