NEN-EN 13381-2:2008 Ontw. en

Beproevingsmethoden voor de bepaling van de bijdrage aan brandwerendheid van draagconstructie-onderdelen - Deel 2: Verticale beschermende membranen

  • Deze norm is ingetrokken sinds 01-05-2012


Over deze norm

Status Ingetrokken
Aantal pagina's 32
Commissie Brandveiligheidsaspecten bouwproducten en bouwdelen
Gepubliceerd op 01-10-2008
Taal Engels
This part of this European Standard specifies a test method for determining the ability of a vertical protective membrane, when used as a fire resistant barrier, to contribute to the fire resistance of loadbearing vertical structural building members fabricated from steel, concrete, steel/concrete composites or timber. The method described is applicable to any type of vertical protective membrane, which can be associated with a separate bracing membrane. The vertical protective membrane can be separate from the structural building member and be selfsupporting or can be attached to the structural building member and can form part of any load bearing structure. This test method is applicable to vertical protective membranes where there is a separating gap of at least 5 mm size between the vertical protective membrane and the structural building member, otherwise alternative test methods prEN 13381-3, prEN 13381-4, prEN 13381-6 or prEN 13381-7 shall be used as appropriate This test method and assessment is not applicable to the following: a) all situations where the cavity behind the vertical protective membrane contains more than a specified amount of combustible materials, e.g. electrical cables and pipes, other than where timber structural members themselves are required; b) all situations where the cavity is to be used as a service or ventilation shaft; c) all situations where the vertical protective membrane acts as a bracing membrane. This European Standard contains the fire test which specifies the tests which shall be carried out whereby the vertical protective membrane together with the structural member to be protected is exposed to the specified fire. The fire exposure, to the standard temperature/time curve given in EN 1363-1, is applied to the side which would be exposed in practice. The test method makes provision, through specified optional additional procedures, for the collection of data which can be used as direct input to the calculation of fire resistance according to the processes given in EN 1992-1-2, EN 1993-1-2, EN 1994-1-2 and EN 1995-1-2. This European Standard also contains the assessment which provides information relative to the analysis of the test data and gives guidance for the interpretation of the results of the fire test, in terms of loadbearing capacity criteria of the protected vertical structural member. The results of the fire test and the assessment can be applied, with certain defined provisions, to vertical structural building members which can be beams, columns or a combination of both and / or which could form part of a separating element or partition. The limits of applicability of the results of the assessment arising from the fire test are defined, together with permitted direct application of the results to different structures, membranes and fittings.


ICS-code 13.220.50
Nederlandse titel Beproevingsmethoden voor de bepaling van de bijdrage aan brandwerendheid van draagconstructie-onderdelen - Deel 2: Verticale beschermende membranen
Engelse titel Test methods for determining the contribution to the fire resistance of structural members - Part 2: Vertical protective membranes
Wordt vervangen door
Normatieve verwijzingen
  • 89/106/EEG, Bouwproducten



Ga naar winkelwagen