Norm

NEN-EN 15058:2004 Ontw. en

Emissies van stationaire bronnen - Referentiemethode voor de bepaling van koolmonoxide in emissies met behulp van de niet-dispersieve infrarood methode

  • Deze norm is ingetrokken sinds 02-06-2006

29,20

Over deze norm

Status Ingetrokken
Aantal pagina's 36
Commissie Emissiemetingen en algemene aspecten
Gepubliceerd op 01-10-2004
Taal Engels
This European Standard specifies the reference method for sampling, and determining carbon monoxide content in ducts and stacks emitting to atmosphere. It describes the Non Dispersive Infra-Red (NDIR) analytical technique, including the sampling system and sample gas conditioning system, to determine CO in flue gases. This European Standard is the reference method for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or others. To be used as the reference method, it is necessary to demonstrate that the performance characteristics of the method are lower than the performance criteria defined in this European standard and that the overall uncertainty of the method is less than ± 6 % relative at the daily Emission Limit Value (ELV). It is necessary for anybody who would like to use an Alternative Method instead of this Standard Reference Method to work out the demonstration of the equivalence according to the Technical Specification TS 14793, providing that his capability to carry out this demonstration is officially recognised by his national accreditation body or law. This reference method has been evaluated during field tests on waste incineration, co-incineration installations and large combustion plants. It has been validated for CO concentrations with sampling periods of 30 min in the range of 0 mg/m3 - 400 mg/m3 for large combustion plants and 0 mg/m3;740 mg/m3 for waste and co-incineration, according to daily emission limit values laid down in the following Council Directives : - Council Directive 2001/80/EC on the limitation of emissions of certain pollutants into the air from large combustion plants - Council Directive 2000/76/EC on waste incineration plants. The limit values of EU directives are expressed in mg/m3, on dry basis and at the reference conditions of 273 K and 101,3 kPa.

Details

ICS-code 13.040.40
Nederlandse titel Emissies van stationaire bronnen - Referentiemethode voor de bepaling van koolmonoxide in emissies met behulp van de niet-dispersieve infrarood methode
Engelse titel Stationary source emissions - Reference method for the determination of carbon monoxide in emission by means of the non-dispersive infrared method
Vervangen door

Winkelwagen

Subtotaal:

Ga naar winkelwagen