Norm

NEN-EN 50121-5:2006 en

Spoorwegen en soortgelijk geleid vervoer - Elektromagnetische compatibiliteit - Deel 5: Emissie en immuniteit van vastopgestelde voedingsinstallaties en apparatuur

  • Deze norm is ingetrokken sinds 23-04-2015

49,30

Over deze norm

Status Ingetrokken
Aantal pagina's 18
Commissie Elektrisch materieel, systemen en elektronische toepassingen voor spoorwegen en soortgelijk geleid vervoer
Gepubliceerd op 01-08-2006
Taal Engels
This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations associated with power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this standard since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment. The limits in this standard do not apply to intentional communication signals. The frequency range considered is from d.c. to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated: a) within the boundary of a substation which delivers electric power to a railway; b) beside the track for the purpose of controlling or regulating the railway power supply, including power factor correction and filtering; c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage. d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes power supplies to marshalling yards, maintenance depots and stations; e) various other non-traction power supplies from railway sources which are shared with railway traction. Apparatus and systems which are in an environment which can be described as residential, commercial or light industry, even when placed within the physical boundary of the railway substation, shall comply with the relevant generic European EMC standard. Excluded from the immunity requirements of this standard is power supply apparatus which is intrinsically immune to the tests defined in Tables 1 to 6 of this standard. These specific provisions are to be used in conjunction with the general provisions in EN 50121-1. This part of the standard covers requirements for both apparatus and fixed installations. The sections for fixed installations are not relevant for CE marking.

Details

ICS-code 29.020
29.280
45.020
Nederlandse titel Spoorwegen en soortgelijk geleid vervoer - Elektromagnetische compatibiliteit - Deel 5: Emissie en immuniteit van vastopgestelde voedingsinstallaties en apparatuur
Engelse titel Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
Vervangt
Wordt vervangen door
Gewijzigd door
Normatieve verwijzingen
  • 2014/30/EU,
  • 96/48/EG, Hogesnelheidstreinen

Winkelwagen

Subtotaal:

Ga naar winkelwagen