Norm

NEN-EN-IEC 61400-25-5:2007 en

Windturbines - Deel 25-5: Communicatie voor bewaking en controle van windkrachtcentrales - Conformiteitsbeproeving

208,31

Over deze norm

Status Definitief
Aantal pagina's 45
Commissie Windturbines
Gepubliceerd op 01-03-2007
Taal Engels
The focus of the IEC 61400-25 series is on the communications between wind power plant components such as wind turbines and actors such as SCADA Systems. Internal communication within wind power plant components is outside the scope of the IEC 61400-25 series. The IEC 61400-25 series is designed for a communication environment supported by a clientserver model. Three areas are defined, that are modelled separately to ensure the scalability of implementations: 1) wind power plant information models, 2) information exchange model, and 3) mapping of these two models to a standard communication profile. The wind power plant information model and the information exchange model, viewed together, constitute an interface between client and server. In this conjunction, the wind power plant information model serves as an interpretation frame for accessible wind power plant data. The wind power plant information model is used by the server to offer the client a uniform, component-oriented view of the wind power plant data. The information exchange model reflects the whole active functionality of the server. The IEC 61400-25 series enables connectivity between a heterogeneous combination of client and servers from different manufacturers and suppliers. As depicted in Figure 1, the IEC 61400-25 series defines a server with the following aspects: - Information provided by a wind power plant component, e. g., "wind turbine rotor speed" or "total power production of a certain time interval" is modelled and made available for access. The information modelled in the standard is defined in part IEC 61400-25-2, - services to exchange values of the modelled information defined in part IEC 61400-25-3, - mapping to a communication profile, providing a protocol stack to carry the exchanged values from the modelled information (part IEC 61400-25-4). The IEC 61400-25 series only defines how to model the information, information exchange and mapping to specific communication protocols. The IEC 61400-25 series excludes a definition of how and where to implement the communication interface, the application program interface and implementation recommendations. However, the objective of the IEC 61400-25 series is that the information associated with a single wind power plant component (such as the wind turbine) is accessible through a corresponding logical device. This part of IEC 61400-25 specifies standard techniques for testing of conformance of implementations, as well as specific measurement techniques to be applied when declaring performance parameters. The use of these techniques will enhance the ability of users to purchase systems that integrate easily, operate correctly, and support the applications as intended.

Details

ICS-code 27.180
Nederlandse titel Windturbines - Deel 25-5: Communicatie voor bewaking en controle van windkrachtcentrales - Conformiteitsbeproeving
Engelse titel Wind turbines - Part 25-5: Communications for monitoring and control of wind power plants - Conformance testing

Winkelwagen

Subtotaal:

Ga naar winkelwagen