NEN-EN-IEC 61558-2-9:2011 en

Veiligheid van energietransformatoren, voedingseenheden en dergelijke - Deel 2-9: Bijzondere bepalingen voor transformatoren voor looplampen van klasse III voor wolfraamdraadlampen

45,28

Over deze norm

Status Definitief
Aantal pagina's 14
Gepubliceerd op 01-03-2011
Taal Engels
This part of IEC 61558 deals with the safety of transformers for class III handlamps for tungsten filament lamps and power supply units incorporating transformers for class III handlamps for tungsten filament lamps. Transformers incorporating electronic circuits are also covered by this standard. Unless otherwise specified, from here onward, the term transformer covers transformers for class III handlamps for tungsten filament lamps and power supply units incorporating transformers for class III handlamps for tungsten filament lamps. This part is applicable to stationary or portable single-phase air-cooled (natural or forced) independent or associated dry-type transformers. The windings may be encapsulated or non-encapsulated. This standard is applicable to transformers and power supply (linear) with internal operational frequencies not exceeding 500 Hz. This standard used in combination with Part 2-16 for switch mode power supply (SMPS) units is also applicable to power supplies with internal operational frequencies higher than 500 Hz. Where the two requirements are in conflict, the most severe take precedence. The rated supply voltage does not exceed 1 000 V a.c., and the rated supply frequency and the internal operational frequencies do not exceed 500 Hz. Transformers for class III handlamps for tungsten filament lamps have the following additional characteristics: - the no-load output voltage and the rated output voltage do not exceed 50 V a.c. or 120 V ripple-free d.c.; - there is only a small difference between the no-load voltage and the rated output voltage. The rated output does not exceed: - 10 kVA. This part is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the end product standard.

Details

ICS-code 29.180
Nederlandse titel Veiligheid van energietransformatoren, voedingseenheden en dergelijke - Deel 2-9: Bijzondere bepalingen voor transformatoren voor looplampen van klasse III voor wolfraamdraadlampen
Engelse titel Safety of transformers, reactors, power supply units and combinations thereof - Part 2-9: Particular requirements and tests for transformers and power supply units for class III handlamps for tungsten filament lamps
Vervangt
Normatieve verwijzingen
  • 2006/95/EG, Laagspanningsrichtlijn nieuw

Winkelwagen

Subtotaal:

Ga naar winkelwagen