Norm

NEN-ISO 10101-3:1996 en

Aardgas - Bepaling van het watergehalte met de methode volgens Karl Fischer - Deel 3: Coulometrische methode

  • Deze norm is ingetrokken sinds 01-04-1998
  • Deze norm is niet direct leverbaar vanuit de NEN-shop.
    Wilt u dit product bestellen neemt u dan contact op met NEN-klantenservice: (015) 2 690 391 of klantenservice@nen.nl

Over deze norm

Status Ingetrokken
Aantal pagina's 6
Commissie Aardgas
Gepubliceerd op 01-01-1996
Taal Engels
The principle of the method specified is passing a measured volume of gas through the titration cell, where the water is absorbed by the anodic solution. The iodine required for the determination of water by the Karl Fischer reaction is generated coulometrically from iodine. The quantity of electricity is directly proportional to the mass of iodine generated and hence to the mass of water determined. Applies to natural gas and other gases which do not react with Karl Fischer reagents. Is applicable to water concentrations between 5 mg/cm³ and 5000 mg/cm³.

Details

ICS-code 75.060
Nederlandse titel Aardgas - Bepaling van het watergehalte met de methode volgens Karl Fischer - Deel 3: Coulometrische methode
Engelse titel Natural gas - Determination of water by the Karl Fischer method - Part 3: Coulometric procedure
Vervangen door

Winkelwagen

Subtotaal:

Ga naar winkelwagen